acq400_configure_transient
Usage
usage: acq400_configure_transient.py [-h] [--pre PRE] [--post POST] [--demux DEMUX] [--clk CLK] [--trg TRG] [--sim SIM] [--trace TRACE]
[--auto_soft_trigger AUTO_SOFT_TRIGGER] [--clear_counters]
uuts [uuts ...]
Positional Arguments
- uuts
uut pairs: m1,m2 [s1,s2 …]
Named Arguments
- --pre
pre-trigger samples
Default: 0
- --post
post-trigger samples
Default: 100000
- --demux
embedded demux
Default: 1
- --clk
int|ext|zclk|xclk,fpclk,SR,[FIN]
- --trg
int|ext,rising|falling
- --sim
s1[,s2,s3..] list of sites to run in simulate mode
- --trace
1 : enable command tracing
- --auto_soft_trigger
force soft trigger generation
Default: 0
- --clear_counters
clear all counters SLOW
Default: False
Outline:
configure transient
configure multiple acq400
positional arguments: uuts uut pairs: m1,m2 [s1,s2 …]
optional arguments: -h, –help show this help message and exit –pre PRE pre-trigger samples –post POST post-trigger samples –clk CLK int|ext|zclk|xclk,fpclk,SR,[FIN] –trg TRG int|ext,rising|falling –sim SIM nosim|s1[,s2,s3..] list of sites to run in simulate mode –trace TRACE 1 : enable command tracing